Setting the Polar Pattern- 10 -Your Classic II can be adjusted to any of nine polar patterns from omni, through cardioid to fi gure of eight. This fl ex
• When in the Figure 8 position (fully clockwise), the microphone picks up sound from in front and behind, and rejects sound from the other two sides
Using the Classic II• The gold dot on the face of the Classic II indicates the front of the microphone, and the pick-up area of the cardioid pattern.
- 13 -.• Placement of the microphone and pop shield relative to the vocalist may be varied on several factors including room acoustics, the vocal per
- 14 -DO NOT DISCONNECT THE MICROPHONE CABLE WHILE THE SYSTEM IS POWERED AS THIS MAY RESULT IN DAMAGE TO THE MICROPHONENEVER REMOVE THE MAINS EARTHDOI
HeadingText- 15 -- 15 -NOTE: There are no user-serviceable parts inside the Classic II supply, but there ARE potentially lethal voltages.If the microp
- 16 -- 16 -WarrantyAll microphones are warranted for one year from date of purchase. You can extend that to a full ten years if you register online
- 2 -IntroductionWe at would like to thank you and congratulate you on investing in the Classic II. This valve microphone represents the finest stu
- 3 -Specifi cationsAcoustic Principle:Pressure gradientDirectional Pattern:Switchable Omnidirectional/ Cardioid / Figure-8 in nine steps(see graph)Fre
- 4 -Specifi cationsFrequency ResponsePolar Response dB re 1 V/Pa 20 10 0 -10 -20 -30 20Hz 100 1000 10 000 20 000 dB re 1 V/Pa 20 10 0
- 5 -Features• Custom spec 1” dual diaphragm capsule• Vintage twin triode GE JAN-6072 valve• Nine polar patterns• Jensen output transformer• Vari
- 6 -Accessories• Transformer (variable polar/pad/fi lter) • SM2 Shock Mount• Double-shielded, oxygen free premium cable• RM2 Stand Mount• RCCL
- 7 -Before Using the Classic II• Ensure that your Classic II has been set to the correct voltage, as used in your country. The Classic II can be use
- 8 -Connecting the Classic II• Having ensured that the power supply is set to the correct voltage you can begin to connect the Classic II to the pow
- 9 -• Now connect an XLR microphone cable to the output socket on the rear of the power supply, taking that output to your mixer/pre-amplifi er.• We